from decimal import Decimal
from .obis_references import *
from .parsers import CosemParser, ValueParser, MBusParser
from .value_types import timestamp
"""
dsmr_parser.telegram_specifications
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
This module contains DSMR telegram specifications. Each specifications describes
how the telegram lines are parsed.
"""
V2_2 = {
EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
ELECTRICITY_USED_TARIFF_1: CosemParser(ValueParser(Decimal)),
ELECTRICITY_USED_TARIFF_2: CosemParser(ValueParser(Decimal)),
ELECTRICITY_DELIVERED_TARIFF_1: CosemParser(ValueParser(Decimal)),
ELECTRICITY_DELIVERED_TARIFF_2: CosemParser(ValueParser(Decimal)),
ELECTRICITY_ACTIVE_TARIFF: CosemParser(ValueParser(str)),
CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
ACTUAL_TRESHOLD_ELECTRICITY: CosemParser(ValueParser(Decimal)),
ACTUAL_SWITCH_POSITION: CosemParser(ValueParser(str)),
TEXT_MESSAGE_CODE: CosemParser(ValueParser(int)),
TEXT_MESSAGE: CosemParser(ValueParser(str)),
EQUIPMENT_IDENTIFIER_GAS: CosemParser(ValueParser(str)),
DEVICE_TYPE: CosemParser(ValueParser(str)),
VALVE_POSITION_GAS: CosemParser(ValueParser(str)),
}
V4 = {
P1_MESSAGE_HEADER: CosemParser(ValueParser(str)),
P1_MESSAGE_TIMESTAMP: CosemParser(ValueParser(timestamp)),
ELECTRICITY_USED_TARIFF_1: CosemParser(ValueParser(Decimal)),
ELECTRICITY_USED_TARIFF_2: CosemParser(ValueParser(Decimal)),
ELECTRICITY_DELIVERED_TARIFF_1: CosemParser(ValueParser(Decimal)),
ELECTRICITY_DELIVERED_TARIFF_2: CosemParser(ValueParser(Decimal)),
ELECTRICITY_ACTIVE_TARIFF: CosemParser(ValueParser(str)),
EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
LONG_POWER_FAILURE_COUNT: CosemParser(ValueParser(int)),
# POWER_EVENT_FAILURE_LOG: ProfileGenericParser(), TODO
VOLTAGE_SAG_L1_COUNT: CosemParser(ValueParser(int)),
VOLTAGE_SAG_L2_COUNT: CosemParser(ValueParser(int)),
VOLTAGE_SAG_L3_COUNT: CosemParser(ValueParser(int)),
VOLTAGE_SWELL_L1_COUNT: CosemParser(ValueParser(int)),
VOLTAGE_SWELL_L2_COUNT: CosemParser(ValueParser(int)),
VOLTAGE_SWELL_L3_COUNT: CosemParser(ValueParser(int)),
TEXT_MESSAGE_CODE: CosemParser(ValueParser(int)),
TEXT_MESSAGE: CosemParser(ValueParser(str)),
DEVICE_TYPE: CosemParser(ValueParser(int)),
INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: CosemParser(ValueParser(Decimal)),
INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE: CosemParser(ValueParser(Decimal)),
INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE: CosemParser(ValueParser(Decimal)),
INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE: CosemParser(ValueParser(Decimal)),
INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE: CosemParser(ValueParser(Decimal)),
INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE: CosemParser(ValueParser(Decimal)),
EQUIPMENT_IDENTIFIER_GAS: CosemParser(ValueParser(str)),
HOURLY_GAS_METER_READING: MBusParser(ValueParser(timestamp),
ValueParser(Decimal))
}