Add 'lib/dsmr_parser_lib/' from commit 'f9e188812fbaee90974a3cddf201bbb40278fd9a'
git-subtree-dir: lib/dsmr_parser_lib git-subtree-mainline:4c0b801f96git-subtree-split:f9e188812f
This commit is contained in:
67
lib/dsmr_parser_lib/dsmr_parser/obis_references.py
Normal file
67
lib/dsmr_parser_lib/dsmr_parser/obis_references.py
Normal file
@@ -0,0 +1,67 @@
|
||||
"""
|
||||
Contains the signatures of each telegram line.
|
||||
|
||||
Previously contained the channel + obis reference signatures, but has been
|
||||
refactored to full line signatures to maintain backwards compatibility.
|
||||
Might be refactored in a backwards incompatible way as soon as proper telegram
|
||||
objects are introduced.
|
||||
"""
|
||||
P1_MESSAGE_HEADER = r'\d-\d:0\.2\.8.+?\r\n'
|
||||
P1_MESSAGE_TIMESTAMP = r'\d-\d:1\.0\.0.+?\r\n'
|
||||
ELECTRICITY_IMPORTED_TOTAL = r'\d-\d:1\.8\.0.+?\r\n'
|
||||
ELECTRICITY_USED_TARIFF_1 = r'\d-\d:1\.8\.1.+?\r\n'
|
||||
ELECTRICITY_USED_TARIFF_2 = r'\d-\d:1\.8\.2.+?\r\n'
|
||||
ELECTRICITY_DELIVERED_TARIFF_1 = r'\d-\d:2\.8\.1.+?\r\n'
|
||||
ELECTRICITY_DELIVERED_TARIFF_2 = r'\d-\d:2\.8\.2.+?\r\n'
|
||||
ELECTRICITY_ACTIVE_TARIFF = r'\d-\d:96\.14\.0.+?\r\n'
|
||||
EQUIPMENT_IDENTIFIER = r'\d-\d:96\.1\.1.+?\r\n'
|
||||
CURRENT_ELECTRICITY_USAGE = r'\d-\d:1\.7\.0.+?\r\n'
|
||||
CURRENT_ELECTRICITY_DELIVERY = r'\d-\d:2\.7\.0.+?\r\n'
|
||||
LONG_POWER_FAILURE_COUNT = r'96\.7\.9.+?\r\n'
|
||||
SHORT_POWER_FAILURE_COUNT = r'96\.7\.21.+?\r\n'
|
||||
POWER_EVENT_FAILURE_LOG = r'99\.97\.0.+?\r\n'
|
||||
VOLTAGE_SAG_L1_COUNT = r'\d-\d:32\.32\.0.+?\r\n'
|
||||
VOLTAGE_SAG_L2_COUNT = r'\d-\d:52\.32\.0.+?\r\n'
|
||||
VOLTAGE_SAG_L3_COUNT = r'\d-\d:72\.32\.0.+?\r\n'
|
||||
VOLTAGE_SWELL_L1_COUNT = r'\d-\d:32\.36\.0.+?\r\n'
|
||||
VOLTAGE_SWELL_L2_COUNT = r'\d-\d:52\.36\.0.+?\r\n'
|
||||
VOLTAGE_SWELL_L3_COUNT = r'\d-\d:72\.36\.0.+?\r\n'
|
||||
INSTANTANEOUS_VOLTAGE_L1 = r'\d-\d:32\.7\.0.+?\r\n'
|
||||
INSTANTANEOUS_VOLTAGE_L2 = r'\d-\d:52\.7\.0.+?\r\n'
|
||||
INSTANTANEOUS_VOLTAGE_L3 = r'\d-\d:72\.7\.0.+?\r\n'
|
||||
INSTANTANEOUS_CURRENT_L1 = r'\d-\d:31\.7\.0.+?\r\n'
|
||||
INSTANTANEOUS_CURRENT_L2 = r'\d-\d:51\.7\.0.+?\r\n'
|
||||
INSTANTANEOUS_CURRENT_L3 = r'\d-\d:71\.7\.0.+?\r\n'
|
||||
TEXT_MESSAGE_CODE = r'\d-\d:96\.13\.1.+?\r\n'
|
||||
TEXT_MESSAGE = r'\d-\d:96\.13\.0.+?\r\n'
|
||||
DEVICE_TYPE = r'\d-\d:24\.1\.0.+?\r\n'
|
||||
INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE = r'\d-\d:21\.7\.0.+?\r\n'
|
||||
INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE = r'\d-\d:41\.7\.0.+?\r\n'
|
||||
INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE = r'\d-\d:61\.7\.0.+?\r\n'
|
||||
INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE = r'\d-\d:22\.7\.0.+?\r\n'
|
||||
INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE = r'\d-\d:42\.7\.0.+?\r\n'
|
||||
INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE = r'\d-\d:62\.7\.0.+?\r\n'
|
||||
EQUIPMENT_IDENTIFIER_GAS = r'\d-\d:96\.1\.0.+?\r\n'
|
||||
# TODO differences between gas meter readings in v3 and lower and v4 and up
|
||||
HOURLY_GAS_METER_READING = r'\d-\d:24\.2\.1.+?\r\n'
|
||||
GAS_METER_READING = r'\d-\d:24\.3\.0.+?\r\n.+?\r\n'
|
||||
ACTUAL_TRESHOLD_ELECTRICITY = r'\d-\d:17\.0\.0.+?\r\n'
|
||||
ACTUAL_SWITCH_POSITION = r'\d-\d:96\.3\.10.+?\r\n'
|
||||
VALVE_POSITION_GAS = r'\d-\d:24\.4\.0.+?\r\n'
|
||||
|
||||
# TODO 17.0.0
|
||||
# TODO 96.3.10
|
||||
|
||||
ELECTRICITY_USED_TARIFF_ALL = (
|
||||
ELECTRICITY_USED_TARIFF_1,
|
||||
ELECTRICITY_USED_TARIFF_2
|
||||
)
|
||||
ELECTRICITY_DELIVERED_TARIFF_ALL = (
|
||||
ELECTRICITY_DELIVERED_TARIFF_1,
|
||||
ELECTRICITY_DELIVERED_TARIFF_2
|
||||
)
|
||||
|
||||
# Alternate codes for foreign countries.
|
||||
BELGIUM_HOURLY_GAS_METER_READING = r'\d-\d:24\.2\.3.+?\r\n' # Different code, same format.
|
||||
LUXEMBOURG_ELECTRICITY_USED_TARIFF_GLOBAL = r'\d-\d:1\.8\.0.+?\r\n' # Total imported energy register (P+)
|
||||
LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL = r'\d-\d:2\.8\.0.+?\r\n' # Total exported energy register (P-)
|
||||
Reference in New Issue