added basic config for DSMR v5 specification; added DSMR v5 example telegram for testing;
This commit is contained in:
@@ -34,8 +34,9 @@ INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE = r'\d-\d:22\.7\.0.+?\r\n'
|
||||
INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE = r'\d-\d:42\.7\.0.+?\r\n'
|
||||
INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE = r'\d-\d:62\.7\.0.+?\r\n'
|
||||
EQUIPMENT_IDENTIFIER_GAS = r'\d-\d:96\.1\.0.+?\r\n'
|
||||
# TODO
|
||||
HOURLY_GAS_METER_READING = r'\d-\d:24\.2\.1.+?\r\n'
|
||||
GAS_METER_READING = r'\d-\d:24\.3\.0.+?\r\n.+?\r\n'
|
||||
GAS_METER_READING = r'(\d-\d:24\.3\.0.+?\r\n.+?\r\n)'
|
||||
ACTUAL_TRESHOLD_ELECTRICITY = r'\d-\d:17\.0\.0.+?\r\n'
|
||||
ACTUAL_SWITCH_POSITION = r'\d-\d:96\.3\.10.+?\r\n'
|
||||
VALVE_POSITION_GAS = r'\d-\d:24\.4\.0.+?\r\n'
|
||||
|
||||
@@ -15,7 +15,7 @@ how the telegram lines are parsed.
|
||||
|
||||
V2_2 = {
|
||||
'checksum_support': False,
|
||||
'objects': {
|
||||
'object_signatures': {
|
||||
obis.EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
|
||||
obis.ELECTRICITY_USED_TARIFF_1: CosemParser(ValueParser(Decimal)),
|
||||
obis.ELECTRICITY_USED_TARIFF_2: CosemParser(ValueParser(Decimal)),
|
||||
@@ -47,12 +47,12 @@ V4 = {
|
||||
'objects': {
|
||||
obis.P1_MESSAGE_HEADER: CosemParser(ValueParser(str)),
|
||||
obis.P1_MESSAGE_TIMESTAMP: CosemParser(ValueParser(timestamp)),
|
||||
obis.EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
|
||||
obis.ELECTRICITY_USED_TARIFF_1: CosemParser(ValueParser(Decimal)),
|
||||
obis.ELECTRICITY_USED_TARIFF_2: CosemParser(ValueParser(Decimal)),
|
||||
obis.ELECTRICITY_DELIVERED_TARIFF_1: CosemParser(ValueParser(Decimal)),
|
||||
obis.ELECTRICITY_DELIVERED_TARIFF_2: CosemParser(ValueParser(Decimal)),
|
||||
obis.ELECTRICITY_ACTIVE_TARIFF: CosemParser(ValueParser(str)),
|
||||
obis.EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
|
||||
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
|
||||
obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
|
||||
obis.LONG_POWER_FAILURE_COUNT: CosemParser(ValueParser(int)),
|
||||
@@ -73,7 +73,46 @@ V4 = {
|
||||
obis.INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE: CosemParser(ValueParser(Decimal)),
|
||||
obis.INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE: CosemParser(ValueParser(Decimal)),
|
||||
obis.EQUIPMENT_IDENTIFIER_GAS: CosemParser(ValueParser(str)),
|
||||
obis.HOURLY_GAS_METER_READING: MBusParser(ValueParser(timestamp),
|
||||
ValueParser(Decimal))
|
||||
obis.HOURLY_GAS_METER_READING: MBusParser(
|
||||
ValueParser(timestamp),
|
||||
ValueParser(Decimal)
|
||||
)
|
||||
}
|
||||
}
|
||||
|
||||
V5 = {
|
||||
'checksum_support': True,
|
||||
'objects': {
|
||||
obis.P1_MESSAGE_HEADER: CosemParser(ValueParser(str)),
|
||||
obis.P1_MESSAGE_TIMESTAMP: CosemParser(ValueParser(timestamp)),
|
||||
obis.EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
|
||||
obis.ELECTRICITY_USED_TARIFF_1: CosemParser(ValueParser(Decimal)),
|
||||
obis.ELECTRICITY_USED_TARIFF_2: CosemParser(ValueParser(Decimal)),
|
||||
obis.ELECTRICITY_DELIVERED_TARIFF_1: CosemParser(ValueParser(Decimal)),
|
||||
obis.ELECTRICITY_DELIVERED_TARIFF_2: CosemParser(ValueParser(Decimal)),
|
||||
obis.ELECTRICITY_ACTIVE_TARIFF: CosemParser(ValueParser(str)),
|
||||
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
|
||||
obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
|
||||
obis.LONG_POWER_FAILURE_COUNT: CosemParser(ValueParser(int)),
|
||||
# POWER_EVENT_FAILURE_LOG: ProfileGenericParser(), TODO
|
||||
obis.VOLTAGE_SAG_L1_COUNT: CosemParser(ValueParser(int)),
|
||||
obis.VOLTAGE_SAG_L2_COUNT: CosemParser(ValueParser(int)),
|
||||
obis.VOLTAGE_SAG_L3_COUNT: CosemParser(ValueParser(int)),
|
||||
obis.VOLTAGE_SWELL_L1_COUNT: CosemParser(ValueParser(int)),
|
||||
obis.VOLTAGE_SWELL_L2_COUNT: CosemParser(ValueParser(int)),
|
||||
obis.VOLTAGE_SWELL_L3_COUNT: CosemParser(ValueParser(int)),
|
||||
obis.TEXT_MESSAGE: CosemParser(ValueParser(str)),
|
||||
obis.DEVICE_TYPE: CosemParser(ValueParser(int)),
|
||||
obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: CosemParser(ValueParser(Decimal)),
|
||||
obis.INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE: CosemParser(ValueParser(Decimal)),
|
||||
obis.INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE: CosemParser(ValueParser(Decimal)),
|
||||
obis.INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE: CosemParser(ValueParser(Decimal)),
|
||||
obis.INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE: CosemParser(ValueParser(Decimal)),
|
||||
obis.INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE: CosemParser(ValueParser(Decimal)),
|
||||
obis.EQUIPMENT_IDENTIFIER_GAS: CosemParser(ValueParser(str)),
|
||||
obis.HOURLY_GAS_METER_READING: MBusParser(
|
||||
ValueParser(timestamp),
|
||||
ValueParser(Decimal)
|
||||
)
|
||||
}
|
||||
}
|
||||
|
||||
Reference in New Issue