added basic config for DSMR v5 specification; added DSMR v5 example telegram for testing;

This commit is contained in:
Nigel Dokter
2017-01-22 16:39:16 +01:00
parent 7a4c204850
commit 45ee8dbb32
4 changed files with 109 additions and 5 deletions

View File

@@ -34,8 +34,9 @@ INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE = r'\d-\d:22\.7\.0.+?\r\n'
INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE = r'\d-\d:42\.7\.0.+?\r\n'
INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE = r'\d-\d:62\.7\.0.+?\r\n'
EQUIPMENT_IDENTIFIER_GAS = r'\d-\d:96\.1\.0.+?\r\n'
# TODO
HOURLY_GAS_METER_READING = r'\d-\d:24\.2\.1.+?\r\n'
GAS_METER_READING = r'\d-\d:24\.3\.0.+?\r\n.+?\r\n'
GAS_METER_READING = r'(\d-\d:24\.3\.0.+?\r\n.+?\r\n)'
ACTUAL_TRESHOLD_ELECTRICITY = r'\d-\d:17\.0\.0.+?\r\n'
ACTUAL_SWITCH_POSITION = r'\d-\d:96\.3\.10.+?\r\n'
VALVE_POSITION_GAS = r'\d-\d:24\.4\.0.+?\r\n'

View File

@@ -15,7 +15,7 @@ how the telegram lines are parsed.
V2_2 = {
'checksum_support': False,
'objects': {
'object_signatures': {
obis.EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
obis.ELECTRICITY_USED_TARIFF_1: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_USED_TARIFF_2: CosemParser(ValueParser(Decimal)),
@@ -47,12 +47,12 @@ V4 = {
'objects': {
obis.P1_MESSAGE_HEADER: CosemParser(ValueParser(str)),
obis.P1_MESSAGE_TIMESTAMP: CosemParser(ValueParser(timestamp)),
obis.EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
obis.ELECTRICITY_USED_TARIFF_1: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_USED_TARIFF_2: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_DELIVERED_TARIFF_1: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_DELIVERED_TARIFF_2: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_ACTIVE_TARIFF: CosemParser(ValueParser(str)),
obis.EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
obis.LONG_POWER_FAILURE_COUNT: CosemParser(ValueParser(int)),
@@ -73,7 +73,46 @@ V4 = {
obis.INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE: CosemParser(ValueParser(Decimal)),
obis.EQUIPMENT_IDENTIFIER_GAS: CosemParser(ValueParser(str)),
obis.HOURLY_GAS_METER_READING: MBusParser(ValueParser(timestamp),
ValueParser(Decimal))
obis.HOURLY_GAS_METER_READING: MBusParser(
ValueParser(timestamp),
ValueParser(Decimal)
)
}
}
V5 = {
'checksum_support': True,
'objects': {
obis.P1_MESSAGE_HEADER: CosemParser(ValueParser(str)),
obis.P1_MESSAGE_TIMESTAMP: CosemParser(ValueParser(timestamp)),
obis.EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
obis.ELECTRICITY_USED_TARIFF_1: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_USED_TARIFF_2: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_DELIVERED_TARIFF_1: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_DELIVERED_TARIFF_2: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_ACTIVE_TARIFF: CosemParser(ValueParser(str)),
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
obis.LONG_POWER_FAILURE_COUNT: CosemParser(ValueParser(int)),
# POWER_EVENT_FAILURE_LOG: ProfileGenericParser(), TODO
obis.VOLTAGE_SAG_L1_COUNT: CosemParser(ValueParser(int)),
obis.VOLTAGE_SAG_L2_COUNT: CosemParser(ValueParser(int)),
obis.VOLTAGE_SAG_L3_COUNT: CosemParser(ValueParser(int)),
obis.VOLTAGE_SWELL_L1_COUNT: CosemParser(ValueParser(int)),
obis.VOLTAGE_SWELL_L2_COUNT: CosemParser(ValueParser(int)),
obis.VOLTAGE_SWELL_L3_COUNT: CosemParser(ValueParser(int)),
obis.TEXT_MESSAGE: CosemParser(ValueParser(str)),
obis.DEVICE_TYPE: CosemParser(ValueParser(int)),
obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE: CosemParser(ValueParser(Decimal)),
obis.EQUIPMENT_IDENTIFIER_GAS: CosemParser(ValueParser(str)),
obis.HOURLY_GAS_METER_READING: MBusParser(
ValueParser(timestamp),
ValueParser(Decimal)
)
}
}